# BMS Integrations

## Overview

myCoreAI connects to a building's existing Building Management System (BMS) to read sensor and meter values and to write the setpoints it has been configured to control. The BMS keeps operational control; only the agreed signals are touched.

**Asset and facility management:** myCoreAI improves user comfort and energy efficiency on the BMS already installed — no controls-hardware replacement.

**Technical operations:** myCoreAI exposes setpoint behavior, bounds, and overrides as auditable signals. The BMS remains the single source of operational truth.

**Integrators:** myCoreAI connects over standard protocols (REST, OPC UA, BACnet, Modbus, or a vendor SDK), with a Myrspoven edge available where direct access isn't viable.

### How the integration works

The communication flow between Myrspoven and the building can happen in one of two main ways:

1. **Direct BMS connection.** myCoreAI connects to the BMS over a network-reachable interface — this is most common when the building can be controlled via a cloud platform or when the local BMS is reachable from the internet through the local firewall. Data flows in both directions on the agreed signal list.
2. **Via Myrspoven edge.** Where direct access isn't viable — closed networks, legacy protocols, segmented IT environments — a small edge application runs on a virtual server inside the building's network and bridges the BMS to the Myrspoven servers. The edge application polls the Myrspoven servers and sends data/retrieves setpoint updates, so no inbound firewall rules are required.

In both scenarios the BMS keeps operational control. myCoreAI reads only the signals it has been configured to read, and writes only the setpoints it has been configured to write.

### Read and write

Reads run on a schedule: every 15 minutes by default for most integrations, every 12 minutes for Web Port, and daily for energy data from Mestro and Metry. The interval can be changed per building. This also applies to buildings connected through the Myrspoven edge: the edge runs the reads and writes the Myrspoven servers schedule for it, at the intervals set for that integration. Schneider EBO pushes its values through its connector instead. Data pushed through the Myrspoven AI-API arrives at the sender's own pace. Streaming integrations are throttled per integration, for example about one value per 15 minutes for Yggio and about every 5 minutes for smart-meter data over MQTT. Common reads include data from indoor sensors (temp, CO₂ and humidity), outdoor temperature, energy meters, current setpoints, and equipment status.

Writes are limited to the setpoints agreed during startup. Typical setpoints are heating-circuit supply temperature setpoints, air handling unit (AHU) supply temperature and fan setpoints, cooling setpoints, and zone-level terminal unit setpoints where the BMS exposes them. myCoreAI writes new setpoint values every 15 minutes, after each successful optimization run.

Each writable setpoint has minimum and maximum bounds agreed up front, and myCoreAI does not push a setpoint outside them. The one exception is the [dew point guard](https://docs.myrspoven.com/how-the-ai-saves-energy/dew-point-function.md), which can raise a chilled-water setpoint to prevent condensation. A manual change in the BMS on a signal myCoreAI controls takes effect immediately and holds until the next write, within 15 minutes, unless AI control is switched off for that signal. Writes can also be paused per building: reads and reporting continue, but actuation stops.

### Fallback, watchdog, and manual override contract

myCoreAI writes after a successful optimization run, normally every 15 minutes. Integration read and write intervals can vary. A missed normal write is not a universal timeout. When writes or AI control are paused, the BMS remains responsible for the building's operational logic.

Each controlled point needs a BMS-side fallback contract before writes are enabled:

* Preserve the native or original BMS setpoint or control curve.
* Select the AI value only when the configured AI-enable condition and valid, fresh-write condition are met.
* On the configured timeout, explicit pause, or safe-control condition, stop selecting the AI value. Resume the preserved native strategy. Do not hold a stale AI value indefinitely.
* Resume AI selection only after the configured recovery condition and valid writes are satisfied.

The integration design must name the owner for every controlled point. That owner creates, maintains, validates, and changes the native fallback strategy or value. The design must also record where it resides: the BMS, an integration or edge script, or the platform. This is integration-specific. myCoreAI does not hold one universal fallback value. Agree and commission it before enabling writes.

The following fields are required commissioning parameters where no common value is documented.

| Contract item                | Direction and owner                                                       | Data type or states                            | Update or event condition                                     | Configured timeout                | Timeout or fail-safe behavior                                          | Recovery                                                                  |
| ---------------------------- | ------------------------------------------------------------------------- | ---------------------------------------------- | ------------------------------------------------------------- | --------------------------------- | ---------------------------------------------------------------------- | ------------------------------------------------------------------------- |
| `AiControlEnabled`           | BMS-side permission state. Owner: named in the site signal list.          | Boolean or agreed states.                      | Changes when AI control is enabled, paused, or made safe.     | Required commissioning parameter. | AI value is not selected when disabled.                                | Use the site-specific enable condition.                                   |
| `AiControlActive`            | BMS-side selection state. Owner: named in the site signal list.           | Boolean or agreed states.                      | Changes when the BMS selects or stops selecting the AI value. | Required commissioning parameter. | Shows that the native strategy is active when AI selection stops.      | Becomes active only when enable, freshness, and recovery conditions pass. |
| `Watchdog` or freshness      | BMS-side evidence of a valid write. Owner: named in the site signal list. | Timestamp, counter, Boolean, or agreed states. | Updated by a valid write within the configured interval.      | Required commissioning parameter. | On expiry, stop selecting the AI value and resume the native strategy. | Reset only by valid writes and the configured recovery condition.         |
| Schneider EBO SmartConnector | Schneider EBO-specific integration.                                       | SmartConnector failsafe.                       | Updated values stop arriving.                                 | 900 seconds.                      | Reverts to default values when the failsafe expires.                   | Follow the documented EBO recovery process.                               |
| Web Port                     | Web Port site integration.                                                | Site-specific signals and script logic.        | Defined in the site signal list.                              | Required commissioning parameter. | Defined by the generated fallback script.                              | Defined by the agreed recovery condition.                                 |

`Myr_D` and `Myr_DS` are Schneider EBO names only. Ouman signal semantics and timeout values are integration-specific and not yet published. Use the agreed site signal list. Do not infer Ouman signal behavior, timeout, or recovery from Schneider EBO or from the normal write cadence.

#### Commission the contract

Before enabling writes, record the configured timeout, owners, storage location, and test results in the site commissioning record.

1. Send a bounded test write. Confirm BMS readback.
2. Simulate loss of valid writes until the configured timeout expires.
3. Confirm the native or original setpoint or control curve takes effect.
4. Pause AI control. Test manual setpoint and control-curve edits.
5. Restore communication. Confirm the configured recovery behavior.

Use the implementation and verification guidance for [Web Port](https://docs.myrspoven.com/connect-your-building/bms-integrations/web-port.md) and the EBO-specific behavior for [Schneider](https://docs.myrspoven.com/connect-your-building/bms-integrations/schneider.md). Customers should use the [FAQ](https://docs.myrspoven.com/get-help/faq.md) for override guidance and [myPortal (classic)](https://docs.myrspoven.com/other-interfaces/myportal.md) for monitoring scope. Only the documented contract for the specified integration applies.

### Supported BMS platforms and protocols

The platforms below are in production today, unless the status says otherwise. They are common delivery paths, not a hard limit on what Myrspoven can connect to.

| Platform                                 | Vendor             | Connection                                                                                                                                | Status                 | Detail    |
| ---------------------------------------- | ------------------ | ----------------------------------------------------------------------------------------------------------------------------------------- | ---------------------- | --------- |
| **Web Port**                             | Kiona              | Local Web Port server (Windows) → Myrspoven Web Port-Cloud; Modbus / BACnet / industrial protocols on the local side                      | In production          | Web Port  |
| **EcoStruxure Building Operation (EBO)** | Schneider Electric | On-premise via Myrspoven edge, or cloud via Schneider SmartConnector; dedicated Read / Write / Overwrite-Bindings folders on the EBO side | In production          | Schneider |
| **Building X (BPCloud)**                 | Siemens            | JSON:API over HTTPS, OAuth2 client credentials. Semantic mapping of tagged equipment/points → Myrspoven components and signals            | In production          | Siemens   |
| **Desigo CC**                            | Siemens            | Legacy on-prem path; requires manual virtual-signal setup in the BMS                                                                      | In production (legacy) | Siemens   |
| **Ouman**                                | Ouman              | Read and write                                                                                                                            | In production          |           |
| **Fidelix Analytics**                    | Fidelix            | Read and write                                                                                                                            | In production          |           |
| **ProptechOS**                           | ProptechOS         | Read and write                                                                                                                            | In development         |           |

### Broader protocol coverage through Web Port

Web Port acts as a protocol gateway. It supports a broad set of drivers for building automation and industrial protocols. That expands the practical integration surface well beyond the named vendors on this page.

If a building exposes the required signals through a Web Port-supported driver, Myrspoven can often integrate without needing a dedicated vendor-specific connector. Final fit still depends on signal availability, write scope, network access, and project requirements.

See [Web Port](https://docs.myrspoven.com/connect-your-building/bms-integrations/web-port.md) and [Web Port driver support](https://kiona.com/products/web-port/driver-support).

For platforms not listed here, contact Myrspoven to assess the best path — direct connector, Web Port, or Myrspoven AI-API.

### What's needed to onboard a new building

The building owner or integrator typically provides:

* A **signal list** for reads and an allowed-setpoint list for writes. Produced together during the technical survey.
* A **point of contact** at the BMS integrator for commissioning.

For a building whose BMS sits behind a firewall and needs the Myrspoven edge, the additional requirements are:

* A **virtual server** in the building's network for the Myrspoven edge (when the Myrspoven edge solution is used).
* **Outbound network access** from that server to the Myrspoven cloud.
* **BMS access** — read and write — on a supported protocol.
* **Temporary VPN access** during edge installation and configuration. No operational traffic uses the VPN.

### Security

All BMS connections are encrypted. Write scope is restricted to the agreed setpoint list and cannot be widened without explicit configuration. The edge polls outbound only — no inbound ports are opened on the building's network.

***


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.myrspoven.com/connect-your-building/bms-integrations.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.